Honeywell Series 3000 MkII Gas Detector Transmitter, with aluminum alloy LM25 housing for monitoring of HYDROGEN SULFIDE (H2S) gas hazards in potentially explosive atmospheres, both in and out of doors using electrochemical sensing technology. Operates on an industry standard 2-wire 4-20mA loop. Optional ranges: 0-15ppm, 0-100ppm

Part# with Options:        S3KUL2-XNXXSH1SS


Honeywell Series 3000 Display

FEATURES

Reliable detection

Reduced installation costs

Reduced commissioning costs

Reduced maintenance costs

Regulatory compliance

Range of optional accessories

Typical applications

Honeywell Series 3000 components

The Series 3000 MkII provides comprehensive monitoring of toxic and oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry standard 2-wire 4-20mA loop, making it ideal for both new and retrofit applications. Users can configure the detector without the need of a ‘hot work permit’ by using the LCD and magnetic switches. Fault diagnostic software and configurable calibration intervals simplify maintenance procedures.

The Intrinsically Safe smart sensors are supplied pre-configured and can be ‘hot swapped’ without having to remove power to the detector, saving time and money during commissioning and routine servicing. A remote sensor mounting kit is available that allows the sensor to be mounted up to 50’ (15m) from the transmitter, making it ideal for operation in areas that are difficult to access.

Series 3000 MkII is supplied with all necessary accessories for easy installation. The detector can be mounted on a wall or support pole using the universal bracket provided. Electrical installation can be made using either conduit or cable with suitable mechanical protection. A ¾” NPT entry and M20 adapter are included as standard. A weatherproof cap is also included for use in the harshest outdoor conditions.


Detectable Gas
Gas Formula Selectable Full Default Range Default Range Operating Temperature**
Min Max
Hydrogen Fluoride H2S 10.0 to 50.0ppm 15.0ppm -40°C / -40°F 55°C / 131°F
Series 3000 MkII Detector
Use Rugged and reliable gas detector for the protection of personnel from toxic and Oxygen gas hazards. Suitable for use in Zone 1 or 2 hazardous areas and North American Class I and II Division 1 or 2 areas.
Electrical
Connections and Power 2-wire loop powered
17VDC (+ / -10%) to 24VDC (max) operation
22mA max. over range
Signal 2-wire with screen (90% coverage) or conduit
0.5mm2 (20AWG) to 2.0mm2 (14AWG)
Connections and Power 0-100% FSD 4-20mA
Fault = 3mA
Calibration due selectable off or 3mA
Max. over range 22mA
Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit
(Oxygen sensors) = Selectable 3mA or 17.4mA
Construction
Material Transmitter: Epoxy painted aluminium alloy LM25 or 316 Stainless Steel
Sensor: 316 Stainless Steel with PTFE filter
Maximum Dimensions 164mm x 201mm x 99mm
6.4″ x 7.9″ x 3.9″
Weight Aluminium alloy LM25: 1.7kg (3.75lbs.) Stainless Steel 316: 3.7kg (8.16lbs.)
Environmental
IP Rating IP66 (EN 60529), NEMA 4X
Certified Temperature ATEX/IECEX: -20°C to +55°C (-4°F to +131°F)
UL/c-UL: -40°C to +55°C (-40°F to +131°F)
Operating Humidity Continuous 20-90% RH (non-condensing)
Intermittent 0-99% RH (non-condensing)
Operating Pressure 90-110kPa
Storage Conditions 15°C to 30°C (59°F to 86°F) 30-70% RH (non-condensing)
Certification UL/c-UL Class I, Div 1 & 2, Groups B, C & D; Class II, Div 1, Groups E, F, G; Class II, Div 2, Groups F & G, Class I Zone 1, Group 2B + H2 Hazardous Locations
ATEX: II 2 (1) G Ex d [ia] IIB+H2 T4 (Tamb -20°C to +55°C / -4°F to 131°F)
IECEx Ex d [ia] IIB + H2 T4
Approvals CE compliant in accordance with:
ATEX Directive 94/9/EC
EMC Directive 2004/108/EC
EN 50270