Honeywell XCD Sensepoint Gas Detector, Infrared Sensor for Propane (C3H8), Ethylene (C2H4), Butane (C4H10) & Pentane (C5H12) combustible 0-100% LEL (Lower Explosive Limit) with Epoxy painted aluminium alloy LM25 housing, stainless steel sensor head, explosion-proof IP66, provides comprehensive monitoring of flammable gas hazards in potentially explosive atmospheres, both indoors and outdoors. 3-wire 24 VDC power, include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable); Modbus RTU option available. User-Selectable full scale range 20%-100%. UL/CSA Class I Division 1 or ATEX IECEx available.

Part# with Options:        SPXCDULNPX


XCD normal display (green) XCD Display in Fault/Warning (Yellow) XCD display in Alarm (Red)
Normal Fault/Warning Alarm

FEATURES

One-Stop Shop

Proven and Reliable Sensor Technology

Global Approvals

Easy to Use

Cost Effective

Simple Installation

Range of Optional Accessories

The Sensepoint XCD range provides comprehensive monitoring of flammable, toxic and Oxygen gas hazards in potentially explosive atmospheres, both indoors and outdoors. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs

Sensepoint XCD ensures easy installation and the fastest routine operation by removing the need for hot work permits in hazardous areas. Using easy to replace plug-in sensors, downtime is also reduced and on-going costs are minimized through the use of poison resistant flammable sensors, poison immune infrared Hydrocarbon sensors and patented SurecellTM toxic sensors and Reflex® sensor health check.

All detectors are supplied pre-configured and include 2 programmable alarm relays, 1 programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and Modbus.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter’s LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Sensepoint XCD has an integral mounting plate for surface mounting or can be mounted to a horizontal or vertical pipe using the optional pipe mounting bracket. Electrical installation can be made using either conduit or cable with suitable mechanical protection. Two M20 or 3⁄4”NPT entries are provided (depending on certification). A weatherproof cap is also included for use in the harshest outdoor conditions. Other optional accessories include a sunshade/deluge protection, duct mounting kit and collecting cone.

TYPICAL APPLICATIONS

Honeywell XCD detector components

1 Cover
2 Display module
3Terminal area
4 Blanking plug
5 Transmitter
6 Plug-in XCD sensor
7 Sensor retaining ring
8 Integral mounting plate
9 Weather protection assembly
10 Cable/conduit entry (x2)
11 Certification label

There are three different types of the XCD transmitter for use with three different families of sensors.

The mV type transmitter is for use with the mV family of XCD sensors including catalytic sensors to detect flammable gases in the range 0-100%LEL and infrared (IR) sensors for detection of Hydrocarbon gases in the range 0-100%LEL, as well as Carbon Dioxide (CO2) in the range 0-2%Vol.

The EC type transmitter is for use with the EC family of XCD sensors including Carbon Monoxide (CO), Hydrogen Sulfide, (H2S), Hydrogen (H2) and Nitrogen Dioxide (NO2).

The Oxygen transmitter is for use with the Oxygen (O2) XCD sensors.

A transmitter can auto-recognize any sensor from within its sensor family. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly.

Sensepoint XCD uses three instantly recognizable ‘traffic light’ colors to indicate its status. The large tri-color backlit LCD is steady green to indicate normal operation, flashes yellow to indicate a fault/warning and flashes red to indicate an alarm. This allows anyone in the area to clearly see at a glance the status of any detector. This can be particularly useful to identify detector status if the detector is located in a difficult to access area or if a number of detectors are located in the same area.


Specifications
Gas Propane, Ethylene, Butane & Pentane
Sensor Family mV
User Selectable Full Scale Range 20.0 to 100.0%LEL
Default Range 100%LEL
Steps 10%LEL
User Selectable Cal Gas Range 30 to 70% of selected full scale range
Default Cal Point 50%LEL
Response Time (T90) Secs <30
Accuracy <+/-1.5%LEL
Min Operating Temperature -20°C / -4°F
Max Operating Temperature 50°C / 122°F
Default Alarm Point A1 20%LEL ▲
Default Alarm Point A2 40%LEL ▲
General Specifications
Use 3 wire, 4-20mA and RS485 MODBUS output fixed point detector with in-built alarm and fault relays for the protection of personnel and plant from flammable, toxic and Oxygen hazards. Incorporating a transmitter with local display and fully configurable via non-intrusive magnetic switch interface.
Electrical
Input Voltage Range 16 to 32VDC (24VDC nominal)
Max Power Consumption Maximum power consumption is dependent on the type of gas sensor being used. Electrochemical cells = 3.7W, IR = 3.7W and catalytic = 4.9W. Maximum inrush current = 800mA at 24VDC
Current Output Sink or source
Relays 3 x 5A@250VAC. Selectable normally open or normally closed (switch) and energized/de-energised (programmable)
Alarm relays default normally open/de-energized. Fault relay default normally open/energized
Communication RS485, MODBUS RTU
Construction
Material Housing: Epoxy painted aluminium alloy LM25 or 316 stainless steel
Sensor: 316 stainless steel
Weight (approx) Aluminium Alloy LM25: 4.4lbs
316 Stainless Steel: 11lbs
Mounting Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3″ (2″ nominal)
Cable Entries UL\cUL versions: 2 x ¾”NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating; ATEX/IECEx versions: 2 x M20 cable entries
Environmental
IP Rating IP66 in accordance with EN60529:1992
Certified Temperature Range 40ºF to +149ºF (-40ºC to +65ºC)
Certification
US, Latin America, Canada UL/c-UL – Class I, Division 1, Groups B, C and D, Class I, Division 2, Groups B, C & D, Class II, Division 1, Groups E, F & G, Class II, Division 2, Groups F & G. -40°C to +65°C
European ATEX Ex II 2 GD Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
International IEC Ex d IIC Gb T6 (Ta -40oC to +65oC) Ex tb IIIC T85°C Db IP66
EMC CE: EN50270:2006 EN6100-6-4:2007
Performance UL508; CSA 22.2 No. 152 (flammable gasses, excludes infrared sensors); ATEX, IEC/EN60079-29-1:2007, EN45544, EN50104, EN50271; China: PA Pattern Measurement (for transmitter and toxic gas sensors) “CCCF” Shenyang for Flammable (fire dept approval)

Honeywell Sensepoint XCD Part Number
Honeywell Sensepoint XCD Option Matrix


 SENSORS (REPLACEMENT) > HONEYWELL XCD
SPXCDXSPXSS Replacement Sensor Cartridge for Flammable IR (Infrared) XCD Detector 0-100%LEL Propane (C3H8) (20.0 to 100.0%LEL, 10%LEL) ..


 XCD Data Sheet

 XCD Specifications

 XCD Detectable Gases And Sensor Performance

 XCD Technical Manual

 XCD Remotely Mounted Flammable Gas Sensors

 XCD Technical Manual (with Modbus)

 Honeywell Sensepoint XCD Cross Sensitivity Data and Catalytic Bead Relative Response

 Honeywell Sensepoint XCD Calibration Guide