The Xgard range is a comprehensive selection of fixed multi gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations
Model: Xgard
Manufacturer : Crowcon Detection Instruments Ltd
Certificate
Gas options | Acetylene (C2H2), Argon (Ar), Arsine (AsH3), Bromine (BR2), Butane (C4H10), Carbon Dioxide (CO2), Diborane (B2H6), Ethane (C2H6), Ethylene (C2H4), Ethylene oxide (C2H4O), Germane (GeH4), Helium (He), LPG, Pentane (C5H12), Petrol vapour, Propane (C3H6), Silane (SiH4), Vinyl chloride (VCM) (CH2 = CHCI, Volatile organics (VO), Ammonia (NH3), Carbon monoxide (CO), Chlorine (Cl2), Chlorine dioxide (ClO2), Fluorine (F2), Hydrogen (H2), Hydrogen chloride (HCL), Hydrogen cyanide (HCN), Hydrogen fluoride (HF), Hydrogen sulphide (H2S), Methane (CH4), Nitric oxide (NO), Nitrogen dioxide (NO2), Oxygen (O2), Ozone (O3), Phosgene (COCL2), Phosphine (PH3), Sulphur dioxide (SO2) |
---|---|
Number of gases | 1 |
Weight | Type 1 – Nylon: 0.5kg (1.1 lbs) Alloy: 1kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs), Type 2, 3, 5, 6 – Aluminium: 1kg (2.2 lbs) Stainless steel: 3.1kg (6.8lbs), Type 4 – 1.5kg (3.3 lbs), Xsafe – 1kg (2.2 lbs) |
Type 1 | Type 2 | Type 3 | Type 4 | Type 5 | Type 6 | Xsafe | ||
Size | 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) | 195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches) | |||||
Weight | Nylon: 0.5 kgAlloy: 1kg (2.2lbs)316 S/S: 3.1kg (6.8lbs) | Aluminium: 1kg (2.2lbs)Stainless steel: 3.1kg (6.8lbs) | 1.5 kg (3.3lbs) | Aluminium: 1kg (2.2lbs) Stainless steel: 3.1kg (6.8lbs) | 1kg (2.2lbs) | |||
Enclosure material | ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S | Aluminium or 316 Stainless Steel | Aluminium | Aluminium or 316 Stainless Steel | Aluminium | |||
Ingress protection | IP65 | IP54 | IP65 | |||||
Cable entries | 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side | |||||||
Terminations | 0.5 to 2.5mm2 | |||||||
Sensor type | Electrochemical | Catalytic bead | 316 S/S sensor housing with catalytic beads | Catalytic bead | Thermal conductivity | Catalytic bead | ||
Operating temperature | -20 to +50 °C (-4 to 122 °F) (sensor dependant) | -20 to +50°C (-4 to 122°F) | -40 to +80°C (-40 to 176°F) | -20 to +150°C (-4 to 302°F) | -40 to +55°C (-40 to 131°F) | +10 to +55°C (50 to 301°F) | mV: -40 to +80oC (-40 to 176oF) mA: -40 to +55oC (-40 to 131oF | |
Humidity | 10 to 95% RH non-condensing | 0-99% RH non-condensing | 0-90% RH | 0-99% RH | ||||
Repeatability Zero drift | <2% FSD (Typical)<2% FSD per Month (Typical) | |||||||
Response time | T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant) | T90 <15s (Typical) | ||||||
Operating voltage | 8-30V dc | 2.0V dc +/- 0.1V (Typical) | 10-30V dc | mA: 10- 30V dc mV:2.0Vdc | ||||
Power requirements | 24mA maximum | 300mA (Typical) | 50mA at 24V dc 1.2W | MA:50mA at 24V dc 1.2W mV: 300mA (Typical) | ||||
Electrical output | 2- wire 4-20mA (current sink) | 3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4 | 3- wire mV bridgeTypical signal: >10mV/%LEL CH4 | 3- wire 4-20mA (current sink or source) | mA: 3- wire 4-20mA (current sink or source) mV: 3- wire mV bridge Typical signal: 12-15mV/ %LEL CH4 | |||
Approvals | ATEX: II 1 G Exia IIC T4 Ga (Tamb -40 to +55°C) UL/cUL: Class I, Div. 1 Groups A, B, C, D IECEx | ATEX: II 2GD Exd IIC T6 Gb (Tamb -40 to +50°C) UL: Class I, Div. 1 Groups B, C, D IECEx | ATEX: II 2 GD Exd IIC T4 Gb (Tamb -40 to +80°C) Exd IIC T6 Gb (Tamb -40 to +50°C) Ex tb IIIC T180°C Db UL: Class I, Div. 1 Groups B, C, D IECEx | ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C) | ATEX/IECEx: II 2 GD
Ex db IIC T4 Gb – Ex tb IIIC T110˚C Db (Tamb -40 to +80˚C) Ex db IIC T6 Gb – Ex tb IIIC T80˚C Db (Tamb -40 to +50˚C) UL : Class I, Div 1 Groups B, C, D | |||
EMC compliance | EN 50270 FCC Part 15 ICES- 003 |
*3/4 ” cable entry only available on aluminium juntion boxes.
Overview
Intrinsically Safe (I.S.) or Flameproof (Exd) versions are available, with case options comprising high-grade alloy, stainless steel or chemically resistant GRN polymer. Certifications include IECEx, ATEX and UL.
Low cost of ownership
Designed for easy installation and maintenance – keeps costs down
Three junction box options – designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
Many spare parts are common to all Xgard models – keeps spares holding requirements to a minimum
Flexible installation options
The Xgard multi gas detectors are designed for either wall or ceiling mounting – no need for additional brackets
Can accommodate M20, 1/2″ NPT or 3/4″ NPT cable glands – suits all site requirements
High temperature models are available for hot environments (up to 150oc)
Accessories are available for duct mounting and sampling applications as well as remote gassing – simple sensor checking
Wide range of sensors
Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
Thermal conductivity sensors are available to monitor % volume concentrations of gases
Rugged and reliable
Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance – designed to operate even in the harshest environments
Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)
88866600 (021)
88317300 (021)
info@novinpetro.com