XgardIQ

The new XgardIQ, our most intelligent fixed gas detector, increases safety by minimising the time operators must spend in hazardous areas. This versatile transmitter and gas detector has a range of features that protect engineers and support facilities managers of oil, gas, chemical & petrochemical plants to name a few. Available fitted with a variety of sensors for flammable, toxic, oxygen or fixed H2S gas detection. (SIL-2) Safety integrity level 2 certified gas monitor

Model: XgardIQ

  • Downloads
  • Specification
  • Description
SizeH278 x W140 x D89mm (10.9 x 5.5 x 3.5 in)
Weight4.1Kg (9lbs)
Enclosure material316 stainless steel
Ingress protectionIP66
ConnectionThree M20 or ½”NPT cable gland entries.Certified, removable plugs are fitted to left-hand and lower righthand entries
Power14-30 VDC. <4W
DisplayMain display – OLED 128 x 64 pixels, yellow text on black background
Indicators – Amber, Red and Green LED’s for detector status; Blue +ve Safety LED
Electrical output4-20mA current sink or source (Auto-Sense or manual selection); warning and fault signals are configurable. NAMUR NE 43 compliant
RS-485 Modbus RTU
HART 7 over 4-20mA signal and via local I.S. test points (optional)
Relays (optional)
Alarm 1, Alarm 2, Fault
SPCO contacts rated 5A, 230Vac
Relay configuration options
Energised or de-energised
Latching or non-latching
Rising or falling
Configurable On and Off delays on alarm relays.
Event loggingRecords alarm, fault and maintenance events. Events can be viewed on-screen and downloaded to a PC.
Operating temperatureTransmitter only: -40°C to +75°C (-40°F to +167°F)†

 

Sensor type:

Oxygen: (-20°C to +50°C ambient)
Toxic: (-40°C to +50°C ambient)
Pellister: (-40°C to +75°C ambient)
Infra-red (IR): (-20°C to +55°C ambient)
High temperature toxic:  (-40⁰C to +70⁰C)

Humidity0 to 95% RH non-condensing†
Repeatability+/- 2% FSD
Zero drift+/- 2% FSD per year maximum
Response timeSensor dependant: contact Crowcon for specific sensor data.
ApprovalsATEX and IECEx:
Ex II 2 G    Ex db ia IIC T4 Gb (see above for temperature ranges)
PerformanceDesigned for compliance with:
EN50104 (oxygen sensors)
EN45544 (toxic gas sensors)*
EN50271 (software)
H2S performance standard
Functional safetyIEC61508, EN50402 SIL 2
EMC ComplianceEN50270:2015
FCC CFR47 Part 15B
ICES-003

† Note: sensor operating temperature and humidity limits vary widely.

* Features outstanding at the time of issue, contact Crowcon for details.

Gases and Ranges

GasUnitsMax
Range
Standard
Range
Alarm 1
level
Alarm 2
level
Temp
range °C 
Oxygen (O2)%Vol302519 (falling)17 (falling)-20 to +50
AmmoniaPPM100/1000502535-20 to +40
 Carbon Monoxide (CO)PPM100025030200 -30 to +50
Hydrogen Fluoride (HF)PPM10101.83+5 to +40
Hydrogen Sulphide (H2S)PPM100/20025510-30 to +50
High Temperature Hydrogen Sulphide (H2S)PPM100/20025510-40 to +70
Ozone (O3)PPM110.10.2-20 to +40
Sulphur Dioxide (SO2)PPM1001011-30 to +50
Hydrogen (H2)%LEL1001002040-40 to +75
Methane (CH4)%LEL1001002040-40 to +75
Pentane (C5H12)%LEL1001002040-40 to +75
Propane (C3H8)%LEL1001002040-40 to +75
Ethanol (IR sensor)%LEL1001002040-20 to +55
LPG (IR sensor)%LEL1001002040-20 to +55
Methane (IR sensor)%LEL1001002040-20 to +55
Propane (IR sensor) %LEL1001002040+10 to + 55

Overview

XgardIQ is an intelligent and versatile fixed detector and transmitter compatible with Crowcon’s full range of sensor technologies. Available fitted with a variety of sensors for fixed flammable, toxic, oxygen or H2S gas detection.

Providing analogue 4-20mA and RS-485 Modbus signals as standard, XgardIQ is optionally available with Alarm and Fault relays and HART communications. The 316 stainless steel are available with three M20 or 1/2“NPT cable entries.

(SIL-2) Safety integrity level 2 certified fixed detector.

Easy and safe to use

  • OLED Display – Bright, clear display indicates gas level and detector status even in dark locations

  • Non-Intrusive Calibration – Zero and calibration functions are performed via the display and keypad, without the need for a hot-work permit or any special tools (e.g. no magnetic wand required)

  • +Ve Safety Indicator – Confirms the detector is operating safely at a glance

  • Event Log Function – Stores all alarm, fault and maintenance events to provide a history of detector use

  • Remote Sensor – Improves probability of detection

Simple installation and maintenance

  • Universal Transmitter – Common transmitter for Crowcon’s full range of sensor technologies

  • Hot-Swap Sensor Modules – Sensors can easily be replaced using one hand without requiring tools or a hot-work permit

  • Auto-Sense Function – Automatically detects whether the control system is 4-20mA current sink or source and sets itself appropriately, eliminating the risk of being incorrectly set

  • Auto-Configure Function – Detects when a sensor module is plugged-in and uploads the appropriate gas type, range, units and alarm levels

Reliability

  • Smart Bump And Speedy Bump Test Functions – Enable sensor health and response to be verified quickly and easily using test gas. Process is automated and provides a reminder when a bump test is due

  • Calibration Due Warning – Reminds the user when calibration is due to ensure that sensors remain operational and accurate at all times

  • Sensor Range Selection – User can set the full-scale range of the sensor via the display menu according to site or specific location requirements.