TECHNICAL DATA:
operating voltage:
24V DC ±10%, protection against reverse polarity
current input:
differs in terms of version up to 40mA
temperature range:
-55°C bis +65°C
degree of protection:
IP 65
case dimensions:
108 x 55mm (h x Ø)
weight:
ca. 1,3kg
measuring value:
vibration acceleration in m/s² or vibration velocity in mm/s
measuring range:
max. 18g Peak or, 12g RMS acc. to 13mm/s RMS fixed value or adjustable with potentiometer or step switch at the range of ±20% or 10 to 100%
signal assessment:
average aligned to root mean square or peak value
frequency range:
10 to 1kHz, frequency range and Bandwidth are in depending on the measurement range 0,5Hz to 1kHz selectable
filter:
Butterworth, 40dB/dec
analog output:
0 to 20mA or 4 to 20mA at supply voltage 4 bis 20mA at current sink also 10mA ±10mA, 0 to 10V or 5V ±5V possible proportional to measurement range
dynamic range:
0 to 25mA, protection against reverse polarity