Photometer for H2S, SO2, chlorine, and oil in water. FPA 4100 monitors specific compounds in both gas and liquid samples
Model: FPA 4100™ PHOTOMETER
Manufacturer : Galvanic Applied Sciences Inc.
DOWNLOADS
MEASUREMENT CERTAINTY
Continuous measurement without the need for reagents or compressed gases
Cell may be installed in a bypass line or in-line; measurement cells may be heating using an oven or by steam jacketing
Linear response to concentration
Multi-stream (up to 8) analysis option
No batch analysis
Temperature-controlled detector block and UV light sources for stability, long lamp life
Dual-wavelength measurement compensates for turbidity, changes in light intensity, optical window coating, and bubbles
Remote monitoring, diagnostics, and control via Ethernet connection
No moving parts are used in the photometer design, assuring high reliability and exceptionally low maintenance
Auto calibration and auto cell washing when required
Automatic lamp-failure detection flagged on the front panel; can also be transmitted via serial and digital output
Photometer for H2S, SO2, chlorine, and oil in water.
FPA 4100 monitors specific compounds in both gas and liquid samples.
Galvanic’s FPA 4100 family of process photometers enables measurement of the concentration of a wide variety of analytes in both liquid and gas streams. The photonics module can accommodate either UV or visible light sources and has a temperature controlled photo diode block for maximum signal stability. The light source and detectors are coupled to a measurement cell via fiber optic cables.
The FPA 4100 controller includes an intuitive user interface with an intrinsically safe, removable keypad, LCD screen, 10 LED indicator lights, and data-loading capability. Rugged and reliable, the systems offer multi-stream-analysis capability, delivering precise continuous measurement with no reagents or compressed gases required. Easy to use and maintain with auto-calibration capability using external standards, auto-zero compensation, and digital optimization of detector gains, the detector electronics are isolated from the process for optimum safety and stability. The FPA 4100 series also enables remote operation and diagnostics via an Ethernet connection.